THIS IS A SOURCES SOUGHT NOTICE ONLY The purpose of this Sources Sought is to conduct market research to procure Brand Name or Equal Dexis Imaging Focus Intraoral Scanner. This notice serves to survey the market to ascertain whether-or-not sources are capable of providing the requested supply. You also must be an Authorized Distributor for Dental Imaging Technologies Corporation or an Authorized Distributor for the manufacture of an equal product if not the manufacture. This notice also allows potential contractors/vendors to submit a non-binding statement of interest and documentation demonstrating their capability. Please review the DRAFT Statement of Work (SOW) to compare your supply/service to what is requested. Complete the line-items below and submit any documentation supporting your product/service for consideration. Regional Procurement Office (RPO) - West is requesting responses from qualified business concerns; the qualifying NAICS code for this effort is 339114 Dental Equipment and Supplies Manufacturing. The Small Business Administration (SBA) Size Standard for this request is 750 employees. This Sources Sought is to gain knowledge of potential qualified sources and their size classification(s) (Service Disabled/Veteran Owned Small Business (SD/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, or large business) relative to NAICS 339114. Responses to this notice, will be used by the Government to make appropriate acquisition decisions. After review of the responses to this notice, a solicitation announcement may be published. Responses to this notice are not considered adequate responses to any corresponding solicitation announcement. All interested offerors are requested to respond to this notice but are required to respond to the official solicitation announcement in order to be awarded the contract. INSTRUCTIONS: RESPONSES MUST INCLUDE THE FOLLOWING INFORMATION: Primary Information: Company Name: Point of Contact (POC) name: Email address: Phone number: Unique Entity ID No. listed in the System of Awards Management (SAM): Business Size: (Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Small Business Other, Small Business, or Large Business) for the NAICS code 339114. IMPORTANT If your firm is a Socio-economic Small Business (SDVOSB, VOSB, Hub zone, 8(a), Small, Small disadvantaged, Woman owned small business), please state if your firm is a Nonmanufacturer under the Nonmanufacturer Rule. For more information about the Nonmanufacturer Rule and how it applies to your firm, click on this Small Business Administration link: https://www.sba.gov/partners/contracting-officials/small-business-procurement/nonmanufacturer-rule Please check the lines below that apply to your firm: a. ____ Business size does not exceed 500 employees. b. ____ Firm is primarily engaged in the retail or wholesale trade and normally sells this type of item being supplies. c. ____ Firm takes ownership or possession of the item(s) with its personnel, equipment, or facilities in a manner consistent with industry practice. d. ____ Supplies the end products of a small business manufacturer or processor made in the United States. If a future solicitation requires the Buy American Statute, the following two clauses will apply: 52.225-1 Buy American-Supplies 52.225-2 Buy American Certificate Please indicate whether you hold a GSA Federal-Supply-Schedule or Indefinite Delivery/Indefinitely Quantity (IDIQ) contract that covers this type of request. If so, please provide the Schedule contract number. Must have an Authorized Distributor Letter issued from the manufacture if not the manufacture. Please specify place of manufacture. The attached SOW is a draft and is NOT finalized. If any portions are unclear, prohibited, and/or you are unsure about the draft description of the requirement please list your comments and/or concerns in your response so they can be addressed. Response is due by 06/12/2025, at 1200PM Central Time. Please submit e-mail responses to Latasha Redwine-Lemons, Contract Specialist, at email address
[email protected]. Please place Dental Intraoral Scanner in the subject line of your email. This notice is to assist the Department of Veterans Affairs in determining qualified sources only. SALIENT CHARACTERISTICS: X6505 - Radiographic Unit, Dental, Panographic Dexis OP 3D Dental Imaging OP 3D Pan Upgradable (2D Unit) Fast Scan 2D panoramic imaging in just 9 seconds Standard and pediatric images, along with bitewing and lateral TMJ projections cover all the extraoral imaging Bitewing-like view is a quick and easy alternative to intraoral bitewing imaging Must be able to provide the optimum panoramic image layer automatically Image volume: 5x5, 6x9, 9x11 Image detector: CMOS Image voxel size: 80-400 micrometer (um) Tube voltage: 95 kV Tube current: 2-12.5mA Easy wheelchair accessibility The device meets the RoHS Directive 2011/65/EU Dimension: 17.7 D x 39.2 W x 96.65 H Quantity: 1 X6600 - Radiographic Unit, Dental, Wall Mounted Dexis FOCUS IntraOral Must include Generator Constant Potential High Voltage DC, 100-200kHz Tube Voltage 60 or 70 kV Tube Current 7 mA Focal Spot 0.7 mm to IEC 60336 Total Filtration 2.0 mm AI (70kV) Line Voltage 115 / 230 VAC +/- 10% 60/50HZ Must have Exposure Time Range 0.02-3.2 seconds Must have reach of 85 inches or 216 cm Must have Beam Limiting Cone Dimensions Round diameter 2.36 inches (60 mm), rectangular 1.38 x 1.77 inches (35 x 45 mm) SSD (Source-Skin Distance): Standard cone 9 inches (229 mm), long cone 12 inches (305 mm) Dimension: 85 D x 46 W x 47 H Quantity: 3 X6610 Sensor, Dental Imaging System Dexis IXS Sensor Must include size 1 (child) and size 2 (standard) Thermoplastic resin coating 2.5 m / 3 mm long Kevlar reinforced cable Pixel size: 19.5 micrometer (um) Number of pixels: Size 1 1.6M (1026 x 1539), size 2 2.4M (1324 x 1842) Resolution: theoretical: 25.6 lp/mm Visible: 20+ lp/mm Must have USB 2.0 port Must be capable with most common image acquisition and clinic management software Sloped dome housing, rounded corners and edges Dimension: 1 D x 1.02 W x 1.42 H Quantity: 3 BRAND NAME OR EQUAL for all line-items listed below. ITEM INFORMATION ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 3.00 EA __________________ __________________ Brand Name or Equal - DEXIS Imaging FOCUS IntraOral X-ray Unit - 85" arm reach PKG A005, LANCASTER CLINIC ACTIVATION MANUFACTURER PART NUMBER (MPN): 0.805.9530 LOCAL STOCK NUMBER: X6600 0002 3.00 EA __________________ __________________ Brand Name or Equal - DEXIS IMAGING IXS COMBO KIT INCLUDES SIZE 1 AND SIZE 2 SENSOR MANUFACTURER PART NUMBER (MPN): 1.013.2916 LOCAL STOCK NUMBER: X6610 0003 1.00 EA __________________ __________________ Brand Name or Equal - DEXIS IMAGING OP 3D PLAN UPGRADABLE (2D UNIT) - 0.805.6300 MANUFACTURER PART NUMBER (MPN): 0.805.6300 LOCAL STOCK NUMBER: X6505 0004 1.00 EA __________________ __________________ INSTALLATION LOCAL STOCK NUMBER: INSTALLATION 0005 1.00 EA __________________ __________________ SHIPPING GRAND TOTAL __________________ NOTES: Issuance of this notice does not constitute any obligation whatsoever on the part of the Government to procure these supplies and/or services, or to issue a solicitation, nor to notify respondents of the results of this notice. No solicitation documents exists at this time; however, in the event the acquisition strategy demonstrates that GSA is a viable option for procuring a solution, the RFQ shall be posted to GSA eBuy where only those firms who currently hold a GSA Schedule with the applicable SIN will be able to respond. The Department of Veterans Affairs is neither seeking quotes nor accepting unsolicited quotes, and responses to this notice cannot be accepted as offers. Any information the vendor considers proprietary should be clearly marked as such. The U.S. Government will not pay for any information or administrative costs incurred in response to this Sources Sought notice.