Federal Contract Opportunity

Last Updated on 17 Jun 2025 at 8 PM
Combined Synopsis/Solicitation
Warner robins Georgia

C-5 Fluid Regulating Valve Repair

Details

Solicitation ID FA8538-25-Q-0009
Posted Date 17 Jun 2025 at 8 PM
Response Date 08 Jul 2025 at 9 PM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Fa8538 Afsc Pzaab
Agency Department Of Defense
Location Warner robins Georgia United states

Possible Bidders

Science Applications International Corporation

San antonio King george Sterling heights Colorado sprin Springfield Warner robins Hyattsville Arlington Vista Stafford Fairfield Torrance Bedford Virginia beach El segundo Bothell Buffalo Mystic Herndon Santa monica Whittier San diego Beltsville Panama city beach Austin Washington Lorton Vienna Columbia Mclean Ridgecrest Colorado springs Reston Las vegas Poway North charleston Tampa Santa maria Marietta Middletown Fairfax Chantilly Havelock Annapolis junction Orlando San jose Indianapolis Oak ridge Crane Cookeville Aurora Bellevue El paso O fallon Chambersburg California Hackensack Sterling Huntsville Mc lean Cape canaveral Rosslyn Panama city Fort worth Falls church

Lockheed Martin Corporation

Saint paul Eatontown Oldsmar Manchester Camden Kekaha Johnson city Hudson Santa margarit Harlingen Moorestown Honolulu Las vegas Boulder Littleton Santa maria Grand prairie Ocala Greenbelt Bellevue Aurora Chambersburg Tinton falls Goleta Kailua Norfolk San antonio Glenside Clarksburg Rcho sta marg Lanham Arlington Troy Killeen Owego Aberdeen proving ground Fort bliss Sunnyvale Gulfport Alpharetta Seabrook Archbald Nashua Gilbert Atlanta Herndon Hoffman estates Baltimore Pomona Centreville Ontario North las vegas Manassas Horsham Liverpool Syracuse Malvern Orlando Chantilly Cherry hill Oak ridge New orleans Riviera beach Cape canaveral Americus Hoffman estate Sarasota Fort worth Colorado sprin Lexington Springfield Ventura Goodyear King of prussia Akron Houston Utica Bethesda Chelmsford Pinellas park Palo alto Burlington Irvine White sands missile range Great neck Merrimack Washington Courtland Bay saint louis Milpitas Johnstown Hightstown San jose Uniondale Titusville Gaithersburg Huntsville Palmdale Santa clara Falls church Yonkers Chesapeake Rockville Warner robins Hurlburt field Eagan Hanover Virginia beach New york Santa cruz San diego Austin Niagara falls Colorado springs Reston King of prussi Marietta Newtown Syosset Fairfax Burbank Mount laurel Buellton Papillion

Supplycore Incorporated

Rockford Santa fe springs North kansas city Atlanta

Science Applications International Corporation

San antonio King george Sterling heights Colorado sprin Springfield Warner robins Hyattsville Arlington Vista Stafford Fairfield Torrance Bedford Virginia beach El segundo Bothell Buffalo Mystic Herndon Santa monica Whittier San diego Beltsville Panama city beach Austin Washington Lorton Vienna Columbia Mclean Ridgecrest Colorado springs Reston Las vegas Poway North charleston Tampa Santa maria Marietta Middletown Fairfax Chantilly Havelock Annapolis junction Orlando San jose Indianapolis Oak ridge Crane Cookeville Aurora Bellevue El paso O fallon Chambersburg California Hackensack Sterling Huntsville Mc lean Cape canaveral Rosslyn Panama city Fort worth Falls church

Science Applications International Corporation

San antonio King george Sterling heights Colorado sprin Springfield Warner robins Hyattsville Arlington Vista Stafford Fairfield Torrance Bedford Virginia beach El segundo Bothell Buffalo Mystic Herndon Santa monica Whittier San diego Beltsville Panama city beach Austin Washington Lorton Vienna Columbia Mclean Ridgecrest Colorado springs Reston Las vegas Poway North charleston Tampa Santa maria Marietta Middletown Fairfax Chantilly Havelock Annapolis junction Orlando San jose Indianapolis Oak ridge Crane Cookeville Aurora Bellevue El paso O fallon Chambersburg California Hackensack Sterling Huntsville Mc lean Cape canaveral Rosslyn Panama city Fort worth Falls church

Sign up to access Documents

Signup now

C-5 Fluid Regulating Valve
NSN: 4820-00-185-1032
PN: 7720140-101

This requirement is a one-time, firm-fixed price procurement for repair of the C-5 Fluid Regulating Valve for use on United States Air Force (USAF) aircraft, NSN: 4820-00-185-1032, Part Number 7720140-101, quantity seven (7) each.  The C-5 fluid regulating valve was designed specifically for the C-5 Galaxy aircraft which is a military transport aircraft.  This part is peculiar to and will only be used on the C-5 Aircraft.  The valve, PN 7720140-101, consists of an aluminum alloy housing and cover, a rubber-coated Dacron fabric diaphragm assembly and a mounting bracket. No external controls are required to operate the valve as pressure from the two aircraft liquid nitrogen (LN2) feedlines are fed through the valve, actuating the diaphragm assembly if the pressures are unequal.  The valve senses the differential pressure between the two aircraft liquid nitrogen (LN2) feedline pressures at the fuel tank heat exchanger in the fire suppression system (FSS), then selects and directs the higher pressure to the valve pressure limiter port. The higher pressure is then applied to the Pressure Limiter Valve which monitors the regulator outlet pressure on both the right and left fuel tank systems to prevent fuel tank over-pressurization The Fluid Regulating Valve should be repaired IAW with Air Force (AF) Technical Manual 13F7-19-3 and the attached drawings.

Delivery is 45 days after receipt of (ARO) CARCASS.  All assets will be shipped FOB Origin.

NO TELEPHONE REQUESTS WILL BE HONORED, and no hard copies will be mailed out.

This proposed contract action is a 100% full and open competition, IAW FAR 6.101(a) and FAR 13.104 . All responsible sources may submit a quotation, which shall be considered by the agency. Additional supporting documentation may be required after receipt of quoatation.

Quotes will be evaluated, and award made in accordance with the attached Request for Quote (RFQ).  All questions regarding the RFQ must be submitted in writing (by email) to:

         [email protected] with a courtesy copy to [email protected].

NO QUESTIONS MAY BE SUBMITTED BY TELEPHONE. All questions and answers will be uploaded to www.SAM.gov. However, the identity of the potential offeror will not be included. Offerors are encouraged to register to receive notification for RFQ and all amendments / revisions and to check the SAM.gov site prior to submission of quote.

Completed Request for Quotes and applicable documents are due 5:30 PM EST, 8 July 2025.

Similar Opportunities

Warren Michigan 15 Jul 2025 at 9 PM
Location Unknown 10 Jul 2025 at 4 AM
Location Unknown 07 Jul 2025 at 4 AM
Location Unknown 14 Jul 2025 at 4 AM
Location Unknown 14 Jul 2025 at 4 AM

Similar Awards

Warren Michigan Not Specified
Location Unknown 13 Jan 2014 at 1 PM
Location Unknown 01 Feb 2008 at 5 AM
Agency Iowa 12 Aug 2015 at 5 PM
Location Unknown 02 May 2011 at 7 PM