Federal Bid

Last Updated on 20 Dec 2002 at 5 AM
Solicitation
Location Unknown

16 -- PISTON SUBASSY SHOCK STRUT MLG

Solicitation ID F42630-02-R-0040
Posted Date 09 Nov 2001 at 5 AM
Archive Date 20 Dec 2002 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Aflcmc / Afsc / Afnwc - Hill Afb
Agency Department Of Defense
Location United states
PR number: FD2020-02-61477 Item 0001 NSN 1620-01-018-4758 P/N: 19042-1, Piston sub assy, MLG. Mfg of chrome plated steel (300M). Wt: 106 lbs. Length 42", width 17", depth 22". 6ea. Alt qty A, 38ea Alt qty B, 70ea Applicable to: A-10. Destn: Hill Air Force Base, Ut 84056-5825. Delivery: 31 DEC 2003 6 ea Alternate delivery quantities: Alt A 31 DEC 2003 38 ea Alt B 31 DEC 2003 70 ea Item 0002 data, 1 lot Qualification requirements: Sources must be qualified prior to being considered for award. The solicitation will contain instructions for obtaining further information on this requirement. The requirements of FAR 9.202(A) have been completed and copies of the qualification requirements and standards may be obtained as described in the solicitation. These qualification requirements apply to line item(s) 0001 Electronic procedure will be used for this solicitation. See our Web page. To: Menasco, Canada. To: West Heights, . To: B F Goodrich, Cleveland Oh 44105-2054. To: Coltec Industries Inc, Euless Tx 76040-7012. To: Eagle Tool, . First article test required. Authority: 10 U.S.C. 2304(C)(1), Justification: Supplies (or Services) required are available from only one or a limited number of responsible source(s) and no other type of supplies or services will satisfy agency requirements. Award will be made only if the offeror, the product/service, or the manufacturer meets qualification requirements at the time of award in accordance with FAR clause 52.209-1. The solicitation identifies the office where additional information can be obtained concerning qualification requirements is cited in each individual solicitation. It is suggested that small business firms or others interested in subcontracting opportunities in connection with the described procurement make contact with the firm(s) listed. An Ombudsman has been appointed to hear concerns from offerors or potential offerors during the proposal development phase of this acquisition. The purpose of the Ombudsman is not to diminish the authority of the program director or contracting officer, but to communicate contractor, concerns, issues, disagreements, and recommendations to the appropriate government personnel. When requested, the Ombudsman will maintain strict confidentiality as to the source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call Roger Porter if your concerns are not satisfied by the contracting officer (801)777-6991. ATTENTION: Contractor must be registered with Central Contractor Registration to be eligible for contact award or payment from any DOD activity. Information on registration and annual confirmation requirements may be obtained by calling 1-888-227-2423, or via the Internet at http://www.ccr2000.com This part required engineering source approval by the design control activity in order to maintain the quality of the part. Existing unique design capability, engineering skills, and manufacturing knowledge by the qualified source(s) require acquisition of the part from the approved source(s). The approved source(s) retain data rights, manufacturing knowledge, or technical data that are not economically available to the Government, and the data or knowledge is essential to maintaining the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. The qualification procedures must be approved by the Government engineering activity having jurisdiction over the part in the intended application. This acquisition involves data that are subject to export control laws and regulations. Only contractors who are registered and certified with the Defense Logistics Services Center (DLSC) shall be provided copies of the solicitation or other data subject to foreign disclosure restrictions. Contact the Defense Logistics Services Center, 74 Washington Avenue N., Battle Creek, Michigan 40917-3084 (1-800-352-3572) for further information on the certification process. You must submit a copy of your approved DD Form 2345, Military Critical Technical Data Agreement, with your request for the solicitation. See Note (s) 22.
Bid Protests Not Available

Similar Past Bids

Location Unknown 28 Feb 2006 at 5 AM
Location Unknown 18 May 2007 at 4 AM
Location Unknown 24 Mar 2008 at 4 PM
Location Unknown 14 Feb 2008 at 5 AM
Location Unknown 20 Mar 2002 at 5 AM

Similar Opportunities

Philadelphia Pennsylvania 21 Jul 2025 at 4 AM
Hill air force base Utah 30 May 2026 at 10 PM
Hill air force base Utah 30 Jun 2026 at 3 PM
Allentown Pennsylvania 14 Jul 2025 at 6 PM
Warner robins Georgia 12 Jul 2025 at 3 AM