16--Technical information on Commercial Off the Shelf (COTS) Altimeter Test Chambers that will provide units with the ability to test and perform minor calibrations on parachutist altimeters.

Solicitation ID W58P0508R0022
Posted Date 30 Apr 2008 at 2 PM
Archive Date 29 Jul 2008 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Not Specified
Agency Department Of Defense
Location Natick Massachusetts United states 01760
The U. S. Army Research Development and Engineering Command (RDECOM) is seeking technical information on Commercial Off the Shelf (COTS) Altimeter Test Chambers that will provide units with the ability to test and perform minor calibrations on parachutist altimeters. The Test Chambers will be used to simulate altitudes as high as 35,000-ft Mean Sea Level.

The Altimeter shall have the following key performance capabilities:

(Threshold (T) is a must-meet criterion; Objective (O) exceeds criterion.)

(1) The Test Chamber will be required to have a accuracy of +/- 50 feet from 0 up to 5,000 feet MSL and +/- 125 feet up to 35,000 feet MSL (T), Accurate +/- 25 feet up to 5,000 feet MSL and +/- 75 feet up to 35,000 feet MSL (O)

(2) Shall be able to be stored in a building that meets storage requirements outlined in TM 10-1670-201-23, at an altitude between 0 and 35,000 feet MSL and a temperature between 41F (5C) and 122F(50C) (T/O).

(3) Shall be operational at an altitude between 0 and 10,000 feet MSL and a temperature between 41F (5C) and 122F(50C). (T/O)

Addition performance capabilities:

(4) Operates on 110 VAC at 50 and 60 Hz (T). Operates on 110 and 220 VAC at 50 and 60 HZ (O).

(5) Must maintain accuracy for a period of 365 days of normal usage before requiring calibration (T/O).

(6) Must be able to have minor calibration conducted by Parachute Rigger (T/O).

(7) Must be contain all equipment required to operate at any altitude other than power source (T/O).

(8) Must be capable of being transported and operated by one person (T/O).

(9) Should be capable of testing 12 altimeters at one time that are similar in size to the MA-230. (T/O).

(10) Altimeter Test Chamber should be enclosed in a rugged container and should pass Transit drop tests in accordance with MIL-STD-810F 516.5 Procedure IV (T/O).

(11) Should not require the use of special tools to operate.

(12) Must utilize a digital display (T/O)



At this time, RDECOM is seeking sources, technical, and product information for an Altimeter Test Chamber that meets the Army's requirements. This market survey is for informational purposes only; this is not a Request for Proposal (RFP). All interested firms, regardless of size, are encouraged to respond to this request for information. Proprietary information will not be disclosed outside the US Government. Responses may be sent via e-mail to [email protected], or by regular mail to US Army RDECOM, SFAE-SDR-CIE (ATTN: Adam Young), Kansas Street, Natick, MA 01760, Telephone (508) 233-5943, Fax (508) 233-6350.





Bid Protests Not Available

Similar Past Bids

Natick Massachusetts 27 May 2016 at 3 PM
Panama city beach Florida 06 Sep 2005 at 5 AM
Wright patterson air force base Ohio 13 May 2011 at 5 PM
Las vegas Nevada 11 Sep 2010 at 3 AM

Similar Opportunities

Oklahoma 10 Jul 2025 at 4 AM (estimated)
Oklahoma 10 Jul 2025 at 4 AM (estimated)
Patuxent river Maryland 01 Aug 2025 at 7 PM
Patuxent river Maryland 01 Aug 2025 at 7 PM
Pennsylvania 15 Jul 2025 at 8 PM