Federal Bid

Last Updated on 03 Nov 2020 at 3 PM
Sources Sought
Altoona Pennsylvania

3510--LAUNDRY EQUIPMENT

Solicitation ID 36C24421Q0069
Posted Date 03 Nov 2020 at 3 PM
Archive Date 09 Dec 2020 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office 244-Network Contract Office 4 (36c244)
Agency Department Of Veterans Affairs
Location Altoona Pennsylvania United states 16602
Sources Sought Notice Electrolux: Washers & Dryer s, (Brand Name or Equal) The Altoona, VA Medical Center located at: 2907 Pleasant Valley Blvd. Altoona, Pennsylvania, is seeking information on potential sources to provide new brand name Electrolux barrier washers and dryers or equal, to be used by Laundry Services in Building 1. The old washers and dryers will be removed under a separate contract. Contractor will be responsible for technical assistance in reviewing final acceptance of the delivered products and giving a brief demonstration on how the product should be installed. However, Installation is not included on this contract. Potential vendors should respond with their ability to provide the following brand name or equal items (two (2): Electrolux Washers, Barrier Washer, Evolution range #WSB5350H; AND one (1): Electrolux Washer, Barrier Washer, Evolution range #WSB5200H; AND two (2): Electrolux Dryer Stack and Single Pocket for OPL Model #T5675),. Brand Name Product: Electrolux Salient Features (Brand Name or Equal) (2) Electrolux Washers, Barrier Washer, Evolution range: Pass-through construction with Vertical Hinges with 175-degree opening Automatic drum positioning and locking for loading / unloading ergonomics and safety Controller to allow for 40 factory and 15 customer wash programs Suspended construction to allow a 350G extraction to save energy during drying process Power balance to allow for changes in loading conditions Dimensions: 56.6in width x 54.72in depth x 72.04in high to fit space Capacity: 77 lbs Drum Volume: 350 liter Drum Diameter: 770 mm Extraction: 910 rpm G-Factor: 350 Heat alternatives: 380-400V Electrical: 27 kW Consumption: Water (cold) (liter): 426 Electrical Energy (motor/heating) (kWh): 18.6 Electrical Electrical Connection: Electric Heated: Main Voltage: 400-415V 3 ~ 50/60 Hz 27 kW heating power 28.8 kW total power 3 x 50 fuse Connections: Water Valves: 20 DN Water pressure: 50-300 kPa Capacity at 250 kPA: 70 l/min Drain valve: 75 mm dia. Drain capacity: 240 l/min Required Connection Heights: Space being built to accommodate the cold water, hot water, drain, and vent connection as specified for this model. Sound Levels: 72 dB (A) Heat emission: 3 % of installed power, max Salient Features (Brand Name or Equal): (1) Electrolux Washers, Barrier Washer, Evolution range Pass-through construction with Vertical Hinges with 175-degree opening Automatic drum positioning and locking for loading / unloading ergonomics and safety Controller to allow for 40 factory and 15 customer wash programs Suspended construction to allow a 350G extraction to save energy during drying process Power balance to allow for changes in loading conditions Dimensions: 41.92in width x 54.72in depth x 72.04in high Capacity: 44lbs Drum Volume: 200 liter Drum Diameter: 770 mm Extraction: 910 rpm G-Factor: 350 Heat alternatives: 380-400V Electrical: 13.5 kW Consumption: Water (cold) (liter): 213 Electrical Energy (motor/heating) (kWh): 11.3 Electrical Electrical Connection: Electric Heated: Main Voltage: 400-415V 3 ~ 50/60 Hz 13.5 kW heating power 15 kW total power 3 x 32 fuse Connections: Water Valves: 20 DN Water pressure: 50-300 kPa Capacity at 250 kPA: 70 l/min Drain valve: 75 mm dia. Drain capacity: 240 l/min Required Connection Heights: Space being built to accommodate the cold water, hot water, drain, and vent connection as specified for this model. Sound Levels: 72 dB (A) Heat emission: 3 % of installed power, max Salient Features (Brand Name or Equal) (2) Electrolux Dryer Stack and Single Pocket for OPL Axial airflow, tight construction and reversing cylinders to reduce gas usage by 25% Auto Stop ensures the dryer stops saving energy Extra Large Door for easy loading and unloading Reversing drums reduces energy consumption Dimensions: 37 13/16 in width x 67 7/16 in depth (includes 6 for steam heat) x73 1/8in high Door Open Depth: 99 5/16in (includes 6 for steam heat) Capacity: 83 lbs Cylinder Volume: 675 litre Door Diameter: 810 mm Steam Consumption: 68 kg/hr Air Flow 1380 m3/hr (Steam heat) Electrical: 120 Volt /16A full load / 20A circuit breaker Steam supplied Pressure (Psi/bar): 145/10 Connections: Exhaust Duct: 250mm Exhaust Static Pressure (mbar) (max at 60 Hz) : 1.9 Steam Connection, inlet & condensate: 1MNPT Supply Pressure (bar): 10 Required Connection Heights: Space being built to accommodate the cold water, hot water, drain, and vent connection as specified for this model. All equipment delivered after inspection should have no defects, markings, blemishes, cracks, tears, or any damage that would normally not be apparent in a brand-new model from the manufacturer s store., etc. Delivered items must be inspected for full safety for the transferring party s full acceptance. This is not a not a request for quote or proposals, but merely a means for Market Research. The intent of this Sources Sought Notice is to identify potential Small Businesses especially any SDVOSBs capable of providing the brand name or equal equipment. Information provided by businesses does not necessarily guarantee future contract award. Responses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 333318 (size standard of employees) 1000. Please answer the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? Is your company considered small under the NAICS code identified under this RFI? Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to sub contracted work and completion of job. Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number. If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. Please submit your capabilities in regard to meeting the salient characteristics detailed above, which includes installation and offloading the unit including installation. Please provide your DUNS number. *** Submissions addressing number (10) should show clear, compelling and convincing*** evidence that meet all the salient characteristics. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Specialist: [email protected]. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. All questions regarding this pre-solicitation should be addressed only to: Tyler Karns @ [email protected]. End of Document
Bid Protests Not Available

Similar Past Bids

Altoona Pennsylvania 19 Nov 2020 at 4 PM
White river junction Vermont 04 Jun 2021 at 3 PM
Temple Texas 07 Jun 2021 at 2 PM
Location Unknown 10 Feb 2011 at 3 PM
Cleveland Ohio Not Specified

Similar Opportunities

Puget sound Washington 09 Dec 2025 at 7 PM
Pennsylvania 13 Jul 2025 at 4 AM (estimated)
Pennsylvania 13 Jul 2025 at 4 AM (estimated)
Hill air force base Utah 26 Jul 2025 at 10 PM