Federal Bid

Last Updated on 06 Oct 2014 at 8 AM
Combined Synopsis/Solicitation
Houston Texas

65--580-14-3-167-0454 - Capnograph for sleep lab (Houston) - VA256-14-AP-6561

Solicitation ID VA25614Q1167
Posted Date 31 Jul 2014 at 8 PM
Archive Date 06 Oct 2014 at 5 AM
NAICS Category
Product Service Code
Set Aside Total Small Business (SBA) Set-Aside (FAR 19.5)
Contracting Office Department Of Veterans Affairs Medical Center
Agency Department Of Veterans Affairs
Location Houston Texas United states 77030
RESPSENSE CAPNOGRAPH Product Highlights Widescreen touch panel display Numerical EtCO2 and respiratory rate display MedAir EtCO2 technology 1.5 hours trending of EtCO2 and respiration rate Backlit LCD display Audible and visual alarms Data output via RS-232 port Specifications Dimensions:...................................... 200 (W) x 135 (H) x 50 (D) mm (7.9 x 5.3 x 2 inches) Weight:............................................. 800 grams (1.8 lbs) Power Data Battery charger:................................ 100 - 240 VAC, 50 - 60 Hz Power consumption:......................... 3.6 W at battery operation, 9 W with power supply Input:................................................ 12 VDC, 720mA Operation Working temperature: ..................... 32° to 104°F (0° to +40°C ) Humidity:.......................................... 10 - 90% (non-condensing) Atmospheric pressure: ...................... 645 - 795 mmHg (860 - 1060 hPa) Storage Storage temperature:........................ -4° to +122°F (-20° to +50°C) Humidity:.......................................... 10 - 90% (non-condensing) Atmospheric pressure:....................... Up to 4 atmospheres (83 - 3038 mmHg/110 - 405 hPa) Pump Pump flow:....................................... 75 ml/min Flow accuracy:.................................. ±15ml/min Battery Data Type:................................................. Lithium Ion internal battery, rechargeable Battery capacity:................................ Approximately 8 hours Charging time:.................................. Approximately 17 hours or 2 hours for each hour of use Capnography Measuring Data Respiration range:............................. 3 - 80 respirations/min Update frequency:............................. Once every breath (No Breath alarm after 25 seconds) Respiration accuracy: ..................... 3 - 50 respirations/min ± 2 51 - 80 respirations/min ± 5 EtCO2/CO2 range:.............................. 0 - 99 mmHg, or 0 - 9.9 kPa EtCO2/CO2 accuracy:.......................... ±0.2 kPa / ±2 mmHg, +6% of reading (EtCO2/CO2 reading reaches its steady state accuracy 10 minutes after power up) Update frequency:............................. Once every breath (No Breath alarm after 25 seconds) Trend length:.................................... 1.5 hours
Bid Protests Not Available

Similar Past Bids

Location Unknown 05 Jun 2018 at 11 PM
Location Unknown 13 Aug 2015 at 8 PM
Houston Texas 09 May 2018 at 2 PM

Similar Opportunities