Federal Bid

Last Updated on 05 Apr 2013 at 8 AM
Solicitation
Tucson Arizona

65--678-13-1-063-0425 / VA258-13-AP-0310 Device for Catheter-Based Dilation of Sinus Ostia

Solicitation ID VA25813Q0307
Posted Date 26 Feb 2013 at 6 PM
Archive Date 05 Apr 2013 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office 258-Network Cntrct Off 22g (36c258)
Agency Department Of Veterans Affairs
Location Tucson Arizona United states 85723
Specifications Objective The Surgical Care Line at Southern Arizona VA Health Care System (SAVAHCS) in Tucson, Arizona, requires medical instruments for performing catheter-based dilation of sinus ostia, also known as functional endoscopic dilation of the sinuses. Surgeons use these devices to dilate the sinus openings with the benefit of requiring little to no tissue removal inside the nose and sinuses. This minimally invasive procedure allows for treatment on an outpatient basis and may be used with other medical therapies or sinus surgery techniques, allowing for future treatment options if the condition progresses. The Surgical Care Line requires the Balloon Sinusplasty by Acclarent or a functionally equal device. Requirements " The equipment is FDA-approved for catheter-based dilation of the sinus. " The technology uses small, soft, flexible devices that enter entirely through the nostrils. These devices are designed to gently open blocked sinus openings without tissue or bone removal. " No tissue or bone is removed when using this technology, reducing bleeding associated with the procedure. " While conditions vary with each patient, procedures have a normal recovery time of 24 hours - 48 hours. " This technology is an endoscopic tool and may be used with other medical therapies or sinus surgery techniques. It does not limit future treatment options if you have progressive disease. " The device should be indicated for access and dilatation of the maxillary, sphenoid, and frontal OSTIA, not just the recess. " The device should have an atraumatic light guide cable that can confirm the wire has transverse the true sinus ostia and also that the wire can provide a rail for the balloon to reach distal past a tortuous frontal outflow tract and ostium. This is a brand name or equal to requirement. Please refer to clauses and provisions for instructions on how to bid on brand name or equal to requirements.
Bid Protests Not Available

Similar Past Bids

Harlingen Texas 25 Jul 2014 at 7 PM
Harlingen Texas 01 Aug 2014 at 10 PM
Location Unknown 08 Aug 2013 at 7 PM
Washington District of columbia 09 May 2007 at 4 AM