This is a Sources Sought (SS) Notice only, not a solicitation announcement and should not be considered as such. There is no solicitation available at this time. The Government will not pay for any information received in response to this SS, nor will the Government compensate any respondent for any cost incurred in developing the information provided to the Government. This SS does not constitute a commitment by the Government. Any information provided in response to this market survey will be used for informational purposes only and will not be released. Vendor participation is not a promise of future business with the Government. The purpose of this SS is to conduct Market Research to gain knowledge of potential qualified sources and their size classification and to obtain information on Service Disabled Veteran Owned Small Businesses (SDVOSB) or Veteran Owned Small Businesses (VOSB) or interest, capabilities and qualifications to determine if a set-aside is appropriate. Proposals are NOT being requested or accepted at this time. NAICS Code 334310 (Audio and Video Equipment Manufacturing).
The Department of Veterans Affairs, Network Contracting Office 10, is conducting market research to determine if there are firms capable of providing the following Grason Stadler AudioStar Pro Clinical Two Channel Audiometer. Carefully consider the following prior to submitting your interest in this requirement.
ITEM NUMBER
DESCRIPTION OF SUPPLIES/SERVICES
QUANTITY
UNIT
0001
3.00
EA
Grason Stadler AudioStar Pro Clinical Two-Channel Audiometer with internal display Includes: *Subject Response Hand switch *Headset, Operator/Monitor *Headphones, Assistant (Aux Intercom) *Extension c
LOCAL STOCK NUMBER: 8503179
0002
3.00
EA
Basic 90 dB HL Corner Speakers (2)
LOCAL STOCK NUMBER: SP8A-GSI
0003
3.00
EA
Sound field speaker calibration/installation
LOCAL STOCK NUMBER: 8032
Salient Characteristics
GSI AudioStar Pro Audiometers
Specifications
Dimensions and W x D x H: 20.1 inches x 14.6 inches x 13.2 inches (LCD raised)
Weight 51.0 cm x 37.0 cm x 33.5 cm
Height with LCD lowered: 5.5 inches 14.0 cm
Weight: 17 pounds 7.7 kg
Shipping Weight: 27 pounds 12.25 kg
Power Consumption: 90 Watts
Channels
Two independent Channels
Pure Tone - Channel
1 and Channel 2 Frequency Range
Air Conduction: 125 Hz to 12,000*** Hz
High Frequency:* 8,000 Hz to 20,000 Hz (8 kHz, 9 kHz, 10 kHz, 11.2 kHz, 12.5
kHz, 14 kHz, 16 kHz, 18 kHz*** and 20 kHz***)
Full Frequency Range:* 125 Hz to 20,000 Hz
Bone Conduction: 250 Hz to 8,000 Hz
Sound Field:* 125 Hz to 8,000 Hz
Paired Inserts:* 125 Hz to 8,000 Hz
Frequency Accuracy: ñ 1 %
Total Harmonic Distortion: < 2% (earphones and paired insert phones*)
< 5% (bone vibrator)
Intensity Range **
Air Conduction (TDH): -10 dB HL to 120 dB HL
High Frequency:* -20 dB HL to 100 dB HL (with Sennheiser HDA 200
Phones)
Bone Conduction: -10 dB HL to 75 dB HL (mastoid)
-10 dB HL to 65 dB HL (forehead)
Sound Field:* -10 dB HL to 90 dB HL (basic speakers)
-10 dB HL to 96 dB HL (high performance speakers)
-10 dB HL to 102 dB HL (high performance speakers and
external booster amplifier)
Paired Inserts:* -10 dB HL to 120 dB HL
Masking Intensity Range (Calibrated in effective masking)
Narrow Band Noise: Maximum dB HL is 15 dB below tone
Signal Format
Steady: Tone continuously present.
Pulsed: Tone pulsed 200 msec ON, 200 msec OFF.
FM: Modulation Rate: 5 Hz
Modulation depth +/- 5%
Speech Channel 1 and Channel 2
Microphone: For live voice testing and communications
INT/EXT A & INT/EXT B: Can be utilized for internal wave files or recorded speech
material from an external digital device
Intensity Range:
Air Conduction: -10 dB HL to 100 dB HL for TDH 50 (Linear Type A)
* Optional configuration
** The maximum HL values are applicable to the middle frequencies only
*** RETSPL values interpolated
Responses to this notice shall be e-mailed to John Tschirhart,
[email protected] . Please provide your Dun and Bradstreet number and socio-economic status if you are interested in this contract; additionally, please provide your FSS or VA NAC contract numbers if applicable. Telephone responses will not be accepted. Responses must be received electronically (via email) no later than August 24, 2018 at 4:00pm local time. This notice is to assist the VA in determining sources only. A solicitation is not currently available.
Contracting Office Address:
Department of Veterans Affairs; Network Contracting Office (NCO 10), 3140 Governor s Place Blvd., Suite 210, Kettering, Ohio 45409
Place of Performance:
Chillicothe VA Medical Center, 17273 State Route 104, Bldg. 20, Chillicothe Ohio 45601, USA
Point of Contact(s):
John Tschirhart
Contract Specialist
Bid Protests Not Available