Federal Bid

Last Updated on 05 Jul 2016 at 8 AM
Sources Sought
Location Unknown

65--Sorin X TRA Autotransfusion Systems

Solicitation ID VA24316Q0683
Posted Date 10 Jun 2016 at 2 PM
Archive Date 05 Jul 2016 at 5 AM
NAICS Category
Product Service Code
Set Aside Total Small Business (SBA) Set-Aside (FAR 19.5)
Contracting Office Department Of Veterans Affairs
Agency Department Of Veterans Affairs
Location United states
This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of Small Businesses, including 8(a), Hub Zone and Service Disabled Veteran-Owned firms relative to the North American Industry Classification Code (NAICS) 339113.The Department of Veteran's Affairs is seeking small business manufacturer or distributors of small business manufacturers, of functionally equivalent equipment to all the following: Sorin Xtra Autotransfusion System 75221- Xtra Equipment 110V 50HZ Version 75307-Xvac Vacuum Pump 110V Version ) Essential/significant physical, functional, or performance characteristics. o Must have a full-color LCD display with touch screen technology. o Must have Dual RBC detector technology to allow for high filling of the bowl. o Must have an integrated Hct sensor which provides information on RBC concentration of the inlet blood during fill phase and outlet blood during the empty phase. o Must have a waste line color indicator providing on screen information on the wash quality by a visual indicator. o Must have 4 pivoting wheels with both front and rear handles for maneuverability. o Must have a transparent centrifuge lid to protect the machine from any spillage and allows visibility into the centrifuge. o System must be able to transport more than 6 liters and fluid and maintain stability. o IV poles must have four hooks for bags and a compartment for storage of caps and pens. o Centrifuge Arm must allow for one-hand arm locking/unlocking. o Must have an automatic stop when reservoir is empty. o Must be able to remove >99% of fat particles. o System must have a >92% Heparin, Protein, Aluminum, and Potassium removal rate. o Vacuum must have two power ranges -50 to -300in intra-operative mode and -10 to -100 in post-operative mode. THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 339113 (Surgical Appliances and Supplies Manufacturing). Name of firm, Socio-Economic category of the firm (SDVOSB, VOSB, 8A, HUBZONE or SMALL BUSINESS), complete address, phone & fax number of contact.
Bid Protests Not Available