The Centralized Acquisition Service, VISN 6, Department of Veterans Affairs is seeking sources for the following items for delivery to the VA Medical Center in Fayetteville, North Carolina. Item numbers from Ostomed are being provided for reference purposes. Items with same diameter and lengths are being requested.
10 each- Guide Wire .035 X4" (316-0107); 1 each- Extremifix Cannulated/ Headless Block (316-1250); 1 each- Gauge Depth cannulated 1/6" Guidewire (316-0036); 1 each- Screw Remover Cannulated 2.0/2.4mm (3016-0039); 1 each- 5 Clamp Bone (320-0102); 1 each- Cannulated Drill 2.0/2.4mm (316-01050); 1 each- Screw Countersink Cannulated 2.0/2.4mm (316-0101); 1 each- Screwdriver Cannulated 2.0/2.4mm (316-0102); 3 each- Screw Lag Cannulated 2.4mm X 6mm (319-2406); 3 each- Screw Lag Cannulated 2.4mm X 8mm (319-2408); 3 each- Screw Lag Cannulated 2.4mm X 10mm (319-2410); 3 each- Screw Lag Cannulated 2.4mm X 12mm (319-2412); 6 each- Screw Lag Cannulated 2.4mm X 14mm (319-2414); 6 each- Screw Lag Cannulated 2.4mm X 16mm (319-2416); 6 each- Screw Lag Cannulated 2.4mm X 18mm (319-2418); 3 each- Screw Lag Cannulated 2.4mm X 20mm (319-2420); 3 each- Screw Lag Cannulated 2.4mm X 22mm (319-2422); 3 each- Screw Lag Cannulated 2.4mm X 24mm (319-2424); 3 each- Screw Lag Cannulated 2.4mm X 26mm (319-2426); 3 each- Screw Lag Cannulated 2.4mm X 28mm (319-2428); 3 each- Screw Lag Cannulated 2.4mm X 30mm (319-2430); 3 each- Screw Lag Cannulated 2.0mm X 6mm (319-2006); 3 each- Screw Lag Cannulated 2.0mm X 8mm (319-2008); 3 each- Screw Lag Cannulated 2.0mm X 10mm (319-2010); 6 each- Screw Lag Cannulated 2.0mm X 12mm (319-2012); 6 each- Screw Lag Cannulated 2.0mm X 14mm (319-2014); 6 each- Screw Lag Cannulated 2.0mm X 16mm (319-2016); 3 each- Screw Lag Cannulated 2.0mm X 18mm (319-2018); 3 each- Screw Lag Cannulated 2.0mm X 20mm (319-2020); 3 each- Screw Lag Cannulated 2.0mm X 22mm (319-2022); 1 each- Extremifix Cannulated/Headless Block 3.0/4.0mm (316-1350); 10 each- Guide Wire .045X6" (316-0004); 1 each- Depth Gauge Cannulated 4/6" Guide Wire (3016-0036); 1 each- Cann Screw Remover 2.0/2.4mm & 3.0/4.0mm (316-0039); 1 each- Bone Clamp (320-0102); 1 each- Cannulated Driver Body Stationary (320-0041); 1 each- Cannulated Drill 3.0/4.0mm (316-0005); 1 each- Cannulated Countersink 3.0/4.0mm (316-0001); 1 each- Cannulated Driver-Short 3.0/4.0mm (316-0007); 1 each- Cannulated Driver-Long (316-0002); 2 each- Cannulated Lag Screw 3.0mmX10mm (319-3010); 2 each- Cannulated Lag Screw 3.0mm x 12mm (319-3012); 4 each- Cannulated Lage Screw 3.0mm X 14mm (319-3014); 4 each- Cannulated Lag Screw 3.0mm X 16mm (319-3016); 4 each- Cannulated Lag Screw 3.0mm x 18mm (319-3018); 2 each- Cannulated Lag Screw 3.0mm X 20mm (319-3020); 2 each- Cannulated Lag Screw 3.0mm X 22mm (319-3022); 2 each- Cannulated Lag Screw 3.0mm X 24mm (319-3024); 2 each- Cannulated Lag Screw 3.0mm X 26mm (319-3026); 2 each- Cannulated Lag Screw 3.0mm X 28mm (319-3028); 2 each- Cannulated Lag Screw 3.0mm X 30mm (319-3030); 2 each- Cannulated Lag Screw 3.0mm X 32mm (319-3032); 2 each- Cannulated Lag Screw 3.0mm X 34mm (319-3034); 2 each- Cannulated Lag Screw 3.0mm X 36mm (319-3036); 2 each- Cannulated Lag Screw 3.0mm X 38mm (319-3038); 2 each- Cannulated Lag Screw 3.0mm X 40mm (319-3040); 2 each- Cannulated Lag Screw 4.0mm X 12mm (319-4012); 4 each- Cannulated Lag Screw 4.0mm X 16mm (319-4016); 4 each- Cannulated Lag Screw 4.0mm X 18mm (319-4018); 4 each- Cannulated Lag Screw 4.0mm X 20mm (319-4020); 2 each- Cannulated Lag Screw 4.0mm X 22mm (319-4022); 2 each- Cannulated Lag Screw 4.0mm X 24mm (319-4024); 2 each- Cannulated Lag Screw 4.0mm X 26mm (319-4026); 2 each- Cannulated Lag Screw 4.0mm X 28mm (319-4028); 2 each- Cannulated Lag Screw 4.0mm X 30mm (319-4030); 2 each- Cannulated Lag Screw 4.0mm X 32mm (319-4032); 2 each- Cannulated Lag Screw 4.0mm X 34mm (319-4034); 2 each- Cannulated Lag Screw 4.0mm 36mm (319-4036); 2 each- Cannulated Lag Screw 4.0mm X 38mm (319-4038); 2 each- Cannulated Lag Screw 4.0mm X 40mm (319-4040); 2 each- Cannulated Lag Screw 4.0mm X 44mm (319-4044); 2 each- Cannulated Lag Screw 4.0mm X 48mm (319-4048); 2 each- Cannulated Lag Screw 4.0mm X 52mm (319-4052); 2 each- Cannulated Lag Screw 4.0mm X 14mm (319-4014).
A determination by the Government to compete the proposed procurement based on the responses to this notice is solely within the discretion of the Government. This notice is for informational and planning purposes only, and does not constitute a solicitation or a commitment by the Government to later publish a solicitation. This is not a request for a competitive quotation. No solicitation document is available, and telephone inquiries will not be honored; however, interested parties may submit their product literature for consideration to: VISN 6 CAS; Attn: Dori Dabbs, Contracting Officer; 201 Hay Street, Suite 304; Fayetteville, NC 28301; or e-mail to
[email protected]. Responses received on or before 1:00 PM EST, July 17, 2009, will be considered.
Bid Protests Not Available