This is a pre-solicitation notice only, this document is for information regarding a possible solicitation for the requirement described below. The government reserves the right to solicit or not solicit a requirement referencing the information provided below. In the event a solicitation is issued please follow instructions provided on that solicitation document for date and time of offer due. No response is required with this pre-solicitation notice. TECHNICAL REQUIREMENTS: The Contractor shall provide the full requested quantity of products listed below. Requirement Overview: Salient Characteristics Equipment Requirement: NAME BRAND Medtronic Stealth Station Fusion Cart. QTY. 1 - #9735669TIKIT1 Stealthstation ENT Cart Kit ($99,125.00 EA) QTY. 1 - #9735736 Stealthstation ENT Software ($49,400.00) QTY. 1 - #9735960 ENT Side Emitter ($7,930.00) Equipment Requirement: Electromagnetic technology for image-guided surgery. Must provide imagine registration, visualization, and modeling features. Virtual endoscopy to provide a simulated 3D endoscopic view. Must provide choice of side or flat emitter for easy and safe positioning. Must have Patient registration feature for visual accuracy feedback. Must have 3D modeling to provide enriched visualization of the patient s anatomy and pathology. Unit must have 2 electromagnetic emitter designs and must have each with large tracking volume. The unit must include 1 terabyte solid-state drive for ample space to store large patient exams. System must also include 16GB of RAM memory for fast performance and image manipulation. Surgical navigation system must have a Multi-Dimensional surgical imaging system. There must be storage options for accessories. Complete unit must allow full mobility for use between concurrent theaters/ORs. Navigation equipment must have wireless connectivity to hospital and medical devices, allowing the import and export of exams from anywhere within the hospital network Surgical navigation system Operating system must adapt to any 16:9 aspect ratio with resolutions up to full HD 1920 x 1080, for flexibility utilizing multiple screens in the OR Unit must have digital and analog output that allows integration Complete navigation system must be compatible with a range of operating tables Company must include on-site training and support Scan merge must combine an unlimited number of exams (CT, CTA, MRI, MRA, PET CT). Registration must have FOV scans, back EM Fram, delayed failure message, intuitive touchpoints and streamlines auto refine feature Must have pre-plan surgical path in all three planes with customizable colors, Instrument visibility must show the most rigid navigated instruments
Bid Protests Not Available