This is a REQUEST FOR INFORMATION (RFI) only. Market research is being conducted to determine the amount of qualified and capable businesses that can provide the items requested below. If you believe your firm is able to provide the items requested below, you are encouraged to respond by the due date with all of the required information indicated below in order to be considered. Due date for responses is close of business (4:30PM local time/CT) on Monday, April 27, 2020. Email responses to Susan Eisenschenk at
[email protected]. All questions must be submitted in writing to the Contracting Officer in writing via email. Because this is a request for information only, answers to questions will not be posted. Telephone inquiries will NOT be accepted/returned. Only authorized distributors will be considered in the procurement process.
When submitting a response to this RFI, offerors must include the following:
Indicate socio-economic status
Include picture of offered items and support literature, brochure etc
Indicate any existing Government contract where item(s) may be purchased (i.e. FSS/GSA contract etc)
Point of contact, DUNS number, complete mailing address, telephone number & email address
Proof of authorized distributor status for ALL items submitted for consideration
If suggesting an Or Equal product(s), include information that demonstrates that product(s) meets/exceeds salient characteristics
DISCLAIMER-This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201 (e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
NAICS: 339112
Size Standard: 500 employees
SPECIFICATIONS: Fitting and Testing Audiology Equipment
ZODIAC - SALIENT CHARACTERISTICS
OPERATES IN OTOSUITE SOFTWARE
INTEGRATES WITH OTOSUITE PRODUCTS AND NOAH
CLINICAL TYMPANOMETER
DUAL PROBE OPTION
LIGHT INDICATOR IN THE PROBE AND ON THE SHOULDER BOX
KEVLAR REINFORCED PROBE CABLES
SILICONE SHOULDER STRAP & ENCLOSED BUTTONS FOR EASY CLEANING/INFECTION CONTROL
TRANSPARENT PROBE TIPS
EASYLOCK PROBE TIPS LOCKING SYSTEM
PROBE TONE (226HZ, 678HZ, 800HZ, 1000HZ)
ADMITTANCE RECORDER
B&G TYMPANOGRAMS
AURICAL PMM - SALIENT CHARACTERISTICS
OPERATES IN OTOSUITE SOFTWARE
INTEGRATES WITH OTOSUITE PRODUCTS AND NOAH
NO ADDITIONAL EQUIPMENT REQUIRED FOR SEEMLESS NOAH DATA TRANSFER (I.E AUDIOGRAM)
WIRELESS, SIMULTANEOUS BINAURAL PROBE MIC MEASUREMENT SYSTEM WITH INTEGRATED RECD TRANSDUCERS
2-CHANNEL CAPABILITY THAT ALLOWS FOR MIXING OF MULTIPLE SIGNALS AT CHOSEN SIGNAL-TO-NOISE RATIO SIMULTANEOUSLY
INTEGRATED FOR USE WITH HEARING INSTRUMENT MANUFACTURING SOFTWARE TO PROVIDE AUTOMATED VERIFICATION
PROBETUBE ASSISTANT FOR CAREFREE PROBE TUBE PLACEMENT
ONTOP MODE FOR EASY INTERACTION WITH FITTING MODULES
ONTARGET MODE FOR EASY MATCHING TO TARGET
OPTIONAL PROBES WITH LONG CABLES FOR PEDIATRIC USE
COUPLER MEASUREMENTS FOR RECD STORED IN PROBE
CALIBRATION DATA STORED IN THE PROBES
LISTEN AT THE EARDRUM
INTEGRATED STIMULUS SPEAKER
SMALL FOOTPRINT WITH VESA MOUNTING OPTION
FREESTYLE MODE WITH 2 CHANNEL STIMULUS
FEATURE-2-BENEFIT MODE
TINNITUS VERIFICATION
Required Individual Line Items & Quantity of Items
1 EA 1096 Zodiac SA Diagnostic with Printer and Classic Probe / 8-04-16043
1 EA 1096 Zodiac Insert Phone / 8-75-85400
1 EA 1096 Probe, Quick Check / 8-66-10000
1 EA 1096 QC Home, Device-mount / 8-35-48200
1 EA 1081,PMM CS W/O HI-PRO / 8-04-14547
1 EA 1081 Kit, Vesa Arm, Desk Mount / 8-62-46500
1 EA 1010 NOAHlink / 8-04-02911
1 EA 1066 CD Quicksin Material / 8-49-91300
1 EA Otometrics Advantage Silver / SVC99SILV
(2 each) User Manuals
(1 each) Cleaning Instructions for all equipment, supplies and accessories
Optional Line Items
Trade-In Items (include make, model and serial # of all items to be used as a trade-in)
Product Specifications (CD, PDF or Word)
Discount for Volume Purchase
Expendable Supplies
Maintenance and Full Service Repair Contracts
Warranty Information
In Service Training
BioMed Training
Installation and/or De-Installation Services
Bid Protests Not Available