ITEM NO 0001 QUANTITY 2 UNIT Each UNIT PRICE ______________
AUTOMATED SATELLITE WORK STATIONFFPTwo Automated Satellite Chromosome Aberration Analysis Stations along with accessories to work in conjunction with a High Throughput Metaphase Finding and Scoring System for chromosome aberration analysis.The Automated Satellite Chromosome Aberration Analysis Stations work in conjunction with a High throughput Metaphase Finding System to further enhance sample analysis throughput. The microscope stage co-ordinates of automatically searched metaphase spreads using a High Throughput Metaphase Finding System, are digitally transferred to the Automated Satellite Chromosome Aberration Analysis Stations for rapid relocation for analysis by several Technicians. The equipment consists of a satellite work station with a computer, a bionocular high quality research microscope such as Olympus BX41 or equivalent, single slide automated stage with autofocus utility, a firewire camera, and automated bright field scoring and annotating software.
Specifications: Automated Satellite Workstation:
- 3.2GHz Pentium4 Computer, 512 MbRAM, 120GHD (or above)
- 19" FIat LCD Monitor (or above)
- DVDRW/CDRWith recorder
- High quality binocular research microscope (Olympus BX 41 or equivalent)
- 5 Mpixel Color Firewire Camera
- Single Slide Automated Stage and Focus
- Metaphase Finding and Scoring Software
- Automated Satellite Scoring Software for Semi-Automated Scoring and Annotation
All Satellites should have the following capabilities:
- Semi-Automated Scoring and Annotation for the following assays
- Chromosome Aberration Analysis
- Sister Chromatid Exchange Analysis
- Dicentric Assay Analysis
- Mitotic Index Measurements
Reviewing and Reporting Software:
- Software only review station.
- Review High Magnification Photos of each spread
- Review Annotation Images
- Score from Photos
- Generate Reports
Automated Metaphase Location Software:
- Automated metaphase spread location on samples prepared from human peripheral blood lymphocyte cultures to minimize man-hour requirements for bright field chromosome aberration analysis.
- Saves postage stamp image of each spread for rapid user review.
- Automatically locates spreads under low power and relocates spreads at high power for user evaluation.
- Adaptive Background Correction provides automated adjustment for variation in staining
- Preloaded Search Algorithms for different preparations
- Spread Location Algorithm
- User Modifiable Spread Location Parameters for different preparations
- Automated Statistical Analysis and Report Generation
- Data Review, Visualization, and Reporting capabilities
- GLP Compliance Support
- Provides thru-camera light metering for easy setup of microscope illumination
- User-Adjustable parameters for spread quality control
- Precise scanning and relocation of spreads
Semi Automated Scoring and Annotation:
- Digital transfer of slide co-ordinates from the High Throughput Metaphase Finder
- Ability to "check out" single slide or multiple slides for scoring.
- Permanently lock study to prevent further changes to the experiment data for all slides.
- System Security limits access to unauthorized users.
- Generates summary reports and statistics (chi-square, t-test) for the entire experiment
- Automated Statistical Analysis and Report Generation Eliminates transcription errors.
- Data Review, Visualization and Reporting
- GLP Compliance Support
- Semi-Automated Annotation function
- Automatically relocates spread on slide for scoring under high magnification.
- Should be able to use as an automated one-slide Metaphase Finding System- Metaphase spreads from the most recently reviewed or scanned slide are displayed.
- Automatically relocates spread on slide for scoring under high magnification
- Photo of metaphase spread at high magnification for later review and documentation
- Rapidly enter aberration data using software spreadsheets
NET AMT _____________
ITEM NO 0002 QUANTITY 2 UNIT Each UNIT PRICE _____________
REVIEWING AND REPORTING SOFTWARE:
- Software only review station.
- Review High Magnification Photos of each spread
- Review Annotation Images
- Score from Photos
- Generate Reports
Automated Metaphase Location Software:
- Automated metaphase spread location on samples prepared from human peripheral blood lymphocyte cultures to minimize man-hour requirements for chromosome aberration analysis.
- Saves postage stamp image of each spread for rapid user review.
- Automatically locates spreads under low power and relocates spreads at high power for user evaluation.
- Adaptive Background Correction provides automated adjustment for variation in staining
- Preloaded Search Algorithms for different preparations
- Spread Location Algorithm
- User Modifiable Spread Location Parameters for different preparations
- Automated Statistical Analysis and Report Generation
- Data Review, Visualization, and Reporting capabilities
- GLP Compliance Support
- Provides thru-camera light metering for easy setup of microscope illumination
- User-Adjustable parameters for spread quality control
- Precise scanning and relocation of spreads
Semi Automated Scoring and Annotation:
- Digital transfer of slide co-ordinates from the High Throughput Metaphase Finder
- Ability to "check out" single slide or multiple slides for scoring.
- Permanently lock study to prevent further changes to the experiment data for all slides.
- System Security limits access to unauthorized users.
- Generates summary reports and statistics (chi-square, t-test) for the entire experiment
- Automated Statistical Analysis and Report Generation Eliminates transcription errors.
- Data Review, Visualization and Reporting
- GLP Compliance Support
- Semi-Automated Annotation function
- Automatically relocates spread on slide for scoring under high magnification.
- Should be able to use as an automated one-slide Metaphase Finding System
- Metaphase spreads from the most recently reviewed or scanned slide are displayed.
- Automatically relocates spread on slide for scoring under high magnification
- Photo of metaphase spread at high magnification for later review and documentation
- Rapidly enter aberration data using software spreadsheets
NET AMT _____________
ITEM NO 0003 QUANTITY 3 UNIT Each UNIT PRICE ____________
METAPHASE VIBRATION FREE TABLES
TECHNICAL SPECIFICATIONS:
Isolation Performance @ 5Hz:70-85%
@ 10 Hz: 90%
Natural Frequency 1.9-2.6 Hz
Isolation Method Air suspension
Air Supply Requirements Manual Hand Pump
Leveling Manual
Top Surface Standard FH-Steel laminated with vibration reducing sheet (Specify 'V' after the part number)
Brushed Stainless Steel with mounting holes M6 or 1/4-20 (Specify 'FH' plus tap size and spacing i.e. DT-6050 A FH ü-20 x 1)
Air Pressure Requirements 3-7 kg/cm2 (20-50psi)
Accessories included Hand pump and air valve adjuster
SIZES / WEIGHTS
Quantity (2) (1)
Load Capacity 100 kg 100 kg (221 lb.) (221 lb.)
Top Plate Size 600x500 800x600 (23.6x19.6) (31.5x23.6)Overall 692x540x168 892x640x168 (25.7x22.6x3.1) (35.1x25.2x3.1)
NET AMT _________________
ITEM NO 0004 QUANTITY 3 UNIT Each UNIT PRICE __________
UNINTERRUPTABLE POWER SUPPLY
Minimum Requirements:
$150,000 Lifetime Equipment Protection Policy plus a 2-year repair or replace warranty.
Product Description:
- USB - UPS - 1500 VA - UPS battery - lead acid
- Output connector(s) 8 x power NEMA 5-15
- Output Voltage AC 120 V
- Input Voltage AC 120 V
- Battery Form Factor Plug-in module
- Average Run Time 6.7 min at full load
- Power Provided 1500 VA
- Device Type UPS
- Battery UPS battery - lead acid
- Warranty 2 years warranty
- Form Factor External
Ports/Connectors:
- Output Connections: (8) NEMA 5-15R outlets
- Input Connection Type: NEMA 5-15P
- Cord Length: 6 ft.
-
Communications & Management:
(1) DB9 interface port (RS-232)
(1) SmartSlot card interface
(1) USB port
Power Notes:
- Output power capacity: 1440VA
- Output power capacity: 980 Watts
- Max. Configurable Power: 1440VA
- Max Configurable Power: 980 Watts
- Nominal output voltage: 120V
- Waveform Type: Sinewave
- Nominal Input Voltage: 120V
- Input Frequency: 50/60Hz +/- 3Hz (auto-sensing)
- Input Voltage Range for Main Operations: 82 - 144V
- Input Voltage Adjustable Range for Main Operations: 75 - 154V
Battery Notes:
- Typical backup time at half load: 22.8 minutes
- Battery type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte (leak-proof)
- Typical recharge time: 3 hrs.Surge Protection and Filtering: Surge energy rating: 320 joules
- Filtering: Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
NET AMT ________________
ITEM NO 0005 QUANTITY 1 UNIT Each UNIT PRICE __________
METAPHASE FINDER & SCORING SYSTEM
Equipment, Accessories, and Supplies: A High Throughput Bright Field Metaphase Finding and Scoring System for chromosome aberration analysis.
Summary of Description of the Item:
The Highthroughput Metaphase Finding System automatically locates metaphase spreads, obtained from human peripheral blood lymphocyte cultures, on microscope slides under a brightfield microscops and relocates metaphase spreads for user review and aberration analysis. This High Throughput Metaphase Finding System consists of a Pentium Computer (3.2 GHz), a firewire camera, a highquality microscope, an automated stage with autofocus, and slide vacuum delivery robotics. The computer is loaded with a automated metaphase finding software, an interactive automated scoring and annotation software for different types of cytogenetic applications.
Specifications:
High Throughput Metaphase Finding and Scoring System Hardware:
- 3.2GHz Pentium4 Computer, 512 MbRAM, 120GHD
- 19" FIatLCD Monitor t.
- DVDRW/CDRW recorder
- 5 Mpixel Color Firewire Camera
- BX41 BrightField Microscope
- Single Slide Automated Stage and Focus
150 Slide Vacuum Delivery Robotics
Software Applications:
- Automated Metaphase Location Software
- Semi-Automated Scoring and Annotation
- Dicentric Assay Scoring
- Chromosome Aberration Scoring
- Sister Chromatic Exchange Scoring
- Mitotic Index
Mpixel Color Firewire Camera Sensor:
- Type : 2/3" ICX282AQ progressive scan interline
- CCD color (Bayer Mosaic), 5.0 megapixels
- Resolution : 2580 x 1944 active pixels
- Pixel Size :3.4 um x 3.4 um
- Optical Interface : C-mount, 2/3" optical format for microscope or camera lens
- Digital Output : 8/10-bit digitization, 30-bit color digitization
- Readout Frequency : 20 MHz 8-bit, 10 MHz 10-bit
- Frame Rate : 3.5 fps full resolution 8-bit, higher speeds with binning and ROI functions
Computerized Control of Camera Function:
- Exposure Control : 1.6 milliseconds to 17.9 minutes in 1 microsecond increments
- Binning Modes : 2x2, 3x3, and 4x4 with full color images
- Shutter Control: Electronic Shutter
- ROI: Image size and position control
BrightField Microscope Features (Olympus BX41 or equivalent):
- Designed for performing in bright field light
- Bright 12V/100W halogen light source for transmitted light viewing
- Built-in filters (two neutral density and one daylight balancing) for efficient photomicrography
- Automated inward-facing five-position nosepiece for easy objective rotation
- High-sensitivity fine focusing knob (adjustment gradations: 1 um)
- Illuminator Built-in Kohler illumination for transmitted light
- Condenser (Numerical aperture 1.1), 4x-100x
- 10x, 100x dry plan achromatic objectives
- 0.5x C-Mount Adapter
Single Slide Automated Stage and Focus:
- XY motion: Nanomotors capable of 5 um steps
- Focus: Positioning capable of 0.02 um steps
- Preloaded search patterns
- Focus Algorithms
Slide Vacuum Delivery Robotics capable of handling over 100 slides:
- Automatically delivers and retrieves sequentially ordered slides for unattended high-throughput microscopic
analysis.
- Digitally controlled vacuum pick-up unit.
- Up to 50 slides are stacked in each storage bin, with a maximum capacity of over 100 slides.
- Small laboratory bench top footprint.
- Must handle regular 1 "x3" microscope slides, and should be adaptable to larger slide formats (2"x3", 4"x3").
Automated Metaphase Location Software:
- Automated metaphase spread location on samples prepared from human peripheral blood lymphocyte cultures to minimize man-hour requirements for chromosome aberration analysis.
- Saves postage stamp image of each spread for rapid user review.
- Automatically locates spreads under low power and relocates spreads at high power for user evaluation.
- Adaptive Background Correction provides automated adjustment for variation in staining
- Preloaded Search Algorithms for different preparations
- Spread Location Algorithm
- User Modifiable Spread Location Parameters for different preparations
- Automated Statistical Analysis and Report Generation
- Data Review, Visualization, and Reporting capabilities
- GLP Compliance Support
- Provides thru-camera light metering for easy setup of microscope illumination
- User-Adjustable parameters for spread quality control
- Precise scanning and relocation of spreads
-
Semi Automated Scoring and Annotation:
- Semi-Automated Scoring and Annotation ability for the following assays
- Chromosome Aberration Analysis for genetic toxicology testing of test compounds
- Analysis of Sister Chromatic Exchanges
- Analysis of radiation induced dicentrics
- Measurement of Mitotic Index
- Metaphase spreads from the most recently reviewed or scanned slide are displayed.
- Automatically relocates spread on slide for scoring under high magnification
- Photo of metaphase spread at high magnification for later review and documentation
- Rapidly enter aberration data using software spreadsheets
- Ability to permanently lock study to prevent further changes to the experimental data for all slides.
- System Security limits access to unauthorized users.
- Generates summary reports and statistics (chi-square, t-test) for the entire experiment
Net Amount ____________________
Bid Protests Not Available