This is a combined synopsis/solicitation for commercial itemsprepared in
accordance with the format in Federal Acquisition Regulation (FAR) Subpart
12.6, as supplemented with additional information included in this notice.
This
announcement constitutes the only solicitation; proposals are being
requested
in response to this notice and a written solicitation will NOT be issued.
This
solicitation is being issued as a Request for Quote (RFQ). Submit only
written
quotes for RFQ DE-RQ75-10SW10341. This solicitation document and
incorporated
provisions and clauses are those in effect through Federal Acquisition
Circular
2005-29. This is a GSA acquisition; no open market pricing will be
considered
for award. The associated NAICS code is 541512 with a small business size
standard of $25 million.
This RFQ contains one (1) line item. The line item descriptions are as
follows,
for continuity sake, no or equal can be accepted:
CLIN 0001 QTY 1- PowerEdge R710 with Chassis for Up to Six 3.5-Inch Hard
Drives
12GB Memory (6x2GB), 1066MHz Dual Ranked UDIMMs for 1 Processor, Optimized
Embedded Broadcom, GB Ethernet NICS with TOE and ISCSI Offload Enabled
Embedded Broadcom, GB Ethernet NICS with TOE
E5520 Xeon Processor, 2.26GHz 8M Cache, Turbo, HT, 1066MHz Max Mem
PowerEdge R710 Heat Sink for 1Processor
No Second Processor
146GB 15K RPM Serial-Attach SCSI 3Gbps 3.5in Hotplug Hard Drive
146GB 15K RPM Serial-Attach SCSI 3Gbps 3.5in Hotplug Hard Drive (341-8718)
146GB 15K RPM Serial-Attach SCSI 3Gbps 3.5in Hotplug Hard Drive (341-8718)
146GB 15K RPM Serial-Attach SCSI 3Gbps 3.5in Hotplug Hard Drive (341-8718)
RAID 10 for H700 or PERC 6/i Controllers (341-8701)
PERC 6/i SAS RAID Controller 2x4 Connectors, Internal, PCIe256MB Cache, x6
Chassis
Performance BIOS Setting
Windows Server 2008, Standard x64, Incl Hyper-V, Incl 5 CALs
Intel Gigabit ET NIC,Quad Port, Copper, PCIe-4
iDRAC6 Express
DVD+/-RW, SATA, INTERNAL
Bezel
Riser with 2 PCIe x8 + 2 PCIe x4 Slot
Sliding Ready Rails Without Cable Management Arm
High Output Power Supply Redundant, 870W
Power Cord, NEMA 5-15P to C13, 15 amp, wall plug, 10 feet / 3 meter
Power Cord, NEMA 5-15P to C13, 15 amp, wall plug, 10 feet / 3 meter
QTY. 2 - SAS cable, 4 meter, connects Tape Device to SAS HBA
5 Year Basic Hardware Support
No Onsite Installation
CLIN 0002 QTY 1- PowerEdge R710 with Chassis for Up to Eight 2.5-Inch Hard
Drives
12GB Memory (6x2GB), 1333MHz Dual Ranked UDIMMs for 2 Processors, Optimized
Embedded Broadcom, GB Ethernet NICS with TOE and ISCSI Offload Enabled
Embedded Broadcom, GB Ethernet NICS with TOE
X5570 Xeon Processor, 2.93GHz 8M Cache,Turbo, HT, 1333MHz Max Mem
X5570 Xeon Processor, 2.93GHz 8M Cache,Turbo, HT, 1333MHz Max Mem
PowerEdge R710 Heat Sinks for 2 Processors
50GB Solid State Disk 3Gbps 2.5" HotPlug Hard Drive
50GB Solid State Disk 3Gbps 2.5" HotPlug Hard Drive
RAID 1 for H700 or PERC 6/i Controllers, SSD Hard Drives
PERC 6/i SAS RAID Controller 2x4 Connectors, Internal, PCIe256MB Cache, x8
Chassis
Performance BIOS Setting
Windows Server 2008 Enterprise Edition Includes 25 CALs
Intel PRO 1000VT Quad Port 1GbE NIC, PCIe-4
iDRAC6 Express
DVD+/-RW, SATA, INTERNAL
Bezel
Riser with 2 PCIe x8 + 2 PCIe x4 Slot
Sliding Ready Rails Without Cable Management Arm
High Output Power Supply Redundant, 870W
Power Cord, NEMA 5-15P to C13, 15 amp, wall plug, 10 feet / 3 meter
Power Cord, NEMA 5-15P to C13, 15 amp, wall plug, 10 feet / 3 meter
QTY. 2 - SAS cable, 4 meter, connects Tape Device to SAS HBA
5 Year Basic Hardware Support
No Onsite Installation
CLIN 0003 QTY 1- PowerVault TL2000, 2U Library,LTO4-120, 1 SAS Drive
SAS 5/E HBA, PCI-Express 2X4 (requires 1 SAS cable)
Tape Media for LTO4-120 tape drive, 800GB/1.6TB, 5 Pack
QTY. 2 - SAS cable, 4 meter, connects Tape Device to SAS HBA
5 Year Basic Hardware Support
No Onsite Installation
CLIN 0004 QTY 1- Dell EqualLogic PS4000E, Cost Efficient, High Capacity,
7.2KSATA Drives
16.0 Terabyte capacity 16 X 1TB, 7.2K SATA Dual Controller
5 Year EqualLogic Advanced Software Warranty and Service,7x24 Access
Onsite INSTALLATION and CONFIGURATION of 1 PS system with up to 2 attached
hosts
* Onsite Engineer must be US Citizen and coordinate with Southwesterns IT
Support team in advance of onsite visit.
CLAUSES: The following FAR clauses apply to this solicitation: GSA Contract
Quotes must be signed, dated and received no later than Feb 8, 2010, at
2:00
PM, Central Time at the following email address:
[email protected]
LATE QUOTES: Quotes or modifications of Proposals received at the address
above
after the exact time specified for receipt of proposals WILL NOT be
considered.
All contractors must be registered in the Central Contractor Registration
database located at http://www.ccr.gov prior to any contract award. Please
submit the following information with each quote: Cage Code, DUNS number,
Tax
Identification Number, Prompt Payment Terms, Delivery Time, GSA Contract
Number, Date quote expires, warranty, total price for each line item, total
proposal price, and any technical documentation in sufficient detail to
determine technical acceptability. Failure to provide sufficient technical
detail may result in rejection of your proposal.
For additional information, please contact the Contracting Officer, Jeremy
Chea
at 918-595-6674 or by email at
[email protected]
Bid Protests Not Available