Federal Bid

Last Updated on 22 Feb 2017 at 9 AM
Sources Sought
Location Unknown

Coveralls, Utility, Green (Shipboard

Solicitation ID SPE1C1-17-R-XXX
Posted Date 31 Jan 2017 at 6 PM
Archive Date 22 Feb 2017 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Dla Troop Support - Clothing & Textiles
Agency Department Of Defense
Location United states
Please fill out and return the attached market research survey.

(Coveralls, Utility (PGC 02580))

NSN(S) THIS PROCUREMENT

36S 8405014624009 36R 8405014624011
38S 8405014624017 38R 8405014624022
38L 8405014624032 40S 8405014624038
40R 8405014624039 40L 8405014624058
42S 8405014624063 42R 8405014624143
42L 8405014624294 44S 8405014624298
44R 8405014624320 44L 8405014624346
46S 8405014624361 46R 8405014624375
46L 8405014624439 48R 8405014624679
48L 8405014624906 50R 8405014624911
50L 8405014624926 52R 8405014624930
52L 8405014624960

When Product Demonstration Models are required, TWO coveralls of sample size shall be submitted.

In the event that PDMs are not required two pre-production samples will be required for technical review prior to contractor beginning production.

If technical operation deems it necessary, DLA Troop Support will participate in first lot inspection. Should this occur, a ten day prior notice is required.

LIST OF DOCUMENTS, EXHIBITS, AND OTHER ATTACHMENTS
a. This solicitation/award consists of the following documents, exhibits, and other attachments
b. DSCPM 4155.3, QUALITY SYSTEMS REQUIREMENTS, NOVEMBER 3, 1997.

52.246-11 Higher-Level Contract Quality Requirement (Feb 1999)
ANSI/ISO/ASQ Q9001-2008(excluding para 7.3) or equivalent.
Certification or registration of a contractor's quality system or program is not required by DoD if ISO or ANSI/ASQ standards are used.

GOVERNMENT LABORATORY TESTING OF COMPONENTS FOR ACCEPTANCE PURPOSE.

52.246-9030 SHADE EVALUATION OF CONTRACTOR FURNISHED MATERIALS:
SHADE SAMPLING IS APPLICABLE

The color of the test specimen shall match the standard sample viewed using AATCC Evaluation Procedure 9, Option A, with sources simulating artificial daylight D75 illuminant with a color temperature of 7500 (+/- 200)°K, with illumination of 100 (+/- 20) foot candles, and shall be a good match to the standard sample under incandescent lamplight at 2856 (+/- 200)°K.


FOR SHADE TESTING: THE COMPLETED DD FORM 1222 AND THE SWATCHES SHALL BE FORWARDED TO:
DLA Product Testing Center Analytical
700 Robbins Avenue
Philadelphia, PA 19111
ATTN: BLDG 5D
EMAIL: [email protected]
PHONE: 215-737-3210

FOR PHYSICAL (NON-SHADE) TESTING: IN ACCORDANCE WITH CLAUSE 52.246-9032, THE CONTRACTOR'S APPROVED QUALIFIED LABORATORY WILL BE REQUIRED TO FORWARD A COMPLETED TEST REPORT FOR EACH LOT OF COMPONENTS TO THE ADDRESS BELOW. THE QAR WILL FORWARD THE COMPLETED DD FORM 1222. SAMPLES FOR PHYSICAL TESTING WILL ONLY BE FORWARDED UPON REQUEST TO:
DLA Product Testing Center Analytical
700 Robbins Avenue
Philadelphia, PA 19111
ATTN: BLDG 5D
EMAIL: [email protected]
PHONE: 215-737-3246

THE USE OF ELECTRONIC SUBMISSION OF DD FORM 1222 IS AUTHORIZED.

NOTE: PERMIT 30 WORKING DAYS.

SHADE EVALUATION OF CONTRACTOR FURNISHED The color of the test specimen shall match the standard sample viewed using AATCC Evaluation Procedure 9, Option A, with sources simulating artificial daylight D75 illuminant with a color temperature of 7500 (+/-200) °K , with illumination of 100 (+/- 20) foot candles, and shall be a good match to the standard sample under incandescent lamplight at 2856 (+/- 200) °K.
52.246-15 CERTIFICATE OF CONFORMANCE

52.209-4, 52.209-9P01, WHEN 52.210-9P06 IS NOT INCLUDED, INSERT THE FOLLOWING: "IF THE EXAMINATION INDICATES ONE OF THE FOLLOWING: WHICHEVER IS APPLICABLE:
(1) NO DIMENSIONAL DEFECT IS FOUND AND NO MORE THAN 10% OF THE UNITS EXAMINED ARE FOUND TO CONTAIN MAJOR OR MINOR "A" DEFECTS, OR
(2) NO DIMENSIONAL DEFECT OR SELECTED DEFECT IS FOUND NOR MORE THAN 10% OF UNITS EXAMINED ARE FOUND TO CONTAIN 3 OR 2 POINT DEFECTS, OR
(3) WHEN THE CLASSIFICATION OF DEFECTS CONTAINS ONLY MAJOR OR MINOR DEFECTS OR ONE CLASS OF DEFECTS ONLY, NO DIMENSIONAL DEFECT IS FOUND NOR MORE THAN 10% OF THE UNITS EXAMINED ARE FOUND TO CONTAIN A DEFECT.

INSPECTION AT SOURCE/ACCEPTANCE AT SOURCE

ADDITIONAL INFORMATION FOR ASL:
THE ACCEPTABLE SUPPLIER LISTING (ASL) AND QUALIFIED LABORATORY LISTING (QLL) ARE NO LONGER VALID DOCUMENTS AND WILL NOT BE PUBLISHED IN THE FUTURE. THE POINT OF CONTACT FOR QUESTIONS PERTAINING TO LABORATORIES AND SUPPLIERS IS THE PROCUREMENT BUYER, INDICATED IN THE SOLICITATION OR CONTRACT. QUESTIONS SHOULD BE PROVIDED IN WRITING TO THE DESIGNATED BUYER.

CLAUSE 52.246-9032 IDENTIFICATION OF QUALIFIED LABORATORY AND SOURCE SAMPLING APPLIES.

REVIEW OF THIS ITEM HAS DETERMINED THAT THE SPECIFICATIONS, STANDARDS, PRODUCT DESCRIPTIONS OR OTHER TECHNICAL DATA APPLICABLE TO THIS PROCUREMENT ACTION DO NOT REQUIRE THE USE
OF CLASS I OZONE DEPLETING SUBSTANCES (ODS) OR ODC(S).

Bid Protests Not Available

Similar Past Bids

Elmendorf Texas 20 Sep 2010 at 11 PM
Location Unknown 27 Jul 2009 at 7 PM
Location Unknown 01 Aug 2009 at 1 AM
Location Unknown 01 Mar 2018 at 6 PM
Quantico Virginia 23 Aug 2007 at 4 AM

Similar Opportunities

Georgia 15 Aug 2025 at 4 PM
California 22 Jul 2025 at 11 PM
San joaquin California 11 Jul 2025 at 4 AM
Pennsylvania 23 Jul 2025 at 4 AM (estimated)