ENT FUSION SYSTEM

Solicitation ID 36C25025Q0399
Posted Date 12 Mar 2025 at 2 PM
Archive Date 03 Apr 2025 at 4 AM
NAICS Category
Product Service Code
Set Aside Total Small Business (SBA) Set-Aside (FAR 19.5)
Contracting Office 250-Network Contract Office 10 (36c250)
Agency Department Of Veterans Affairs
Location Detroit Michigan United states 48201

Brand Name Item:  Stealth Station S8 Navigation System
The StealthStation S8 is an intraoperative surgical navigation system that is used to guide ENT procedures.  It is a computer-based workstation that loads MRI and CT scans and used an optical or electromagnetic tracking system that co-registers the patients anatomy with the MRI/CT scans and tracks sterile instruments during surgery.  
Essential/significant physical, functional, or performance characteristics.
Navigation system must have 2 large, high definition, 27-inch touchscreen monitors provide ultimate flexibility in interacting with the system 
 Unit must have 2 electromagnetic emitter designs, and must have each with large tracking volume 
 The unit must include 1 terabyte solid-state drive for ample space to store large patient exams 
 System must also include 16GB of RAM memory for fast performance and image manipulation 
Optical camera must come with large tracking volume provides flexibility in positioning and addresses line of sight issues
Surgical navigation system must have a Multi-Dimensional surgical imaging system
Included must be a dual cart system design: each cart has 27-inch multi-touch monitor and independent workstation for flexibility 
There must be ample storage options for accessories 
 Consistent user interface is essential across all software applications
Equipment must provide both 2D fluoro and 3D image data from the same device
Navigation visuals must enable 3D imaging in the OR for registration, intra-operative adjustments, and implant confirmation
Visualization function must have 3D imaging and visualization of shunts, leads, and electrodes during cranial procedures
Unit must provide flexibility to match image needs intra-operatively
Navigation computer must have assisted navigation and intraoperative imaging during pedicle screw placement in spinal surgery
Surgical system must have breakable gantry that opens to allow lateral patient access
Complete unit must allow full mobility for use between concurrent theaters/ORs
Navigation equipment must have wireless connectivity to hospital and medical devices, allowing the import and export of exams from anywhere within the hospital network 
Automatic patient registration with the O-arm imaging system 
Surgical navigation system Operating system must adapt to any 16:9 aspect ratio with resolutions up to full HD 1920 x 1080, for flexibility utilizing multiple screens in the OR 
 Unit must have digital and analog output that allows integration
Complete navigation system must be compatible with a range of operating tables
Company must include on-site training and support

Applicable model/make/catalog number   9735669TiKIT1, 9735736, 9735960

Manufacturer name   Stealth Navigation System
TECH SPECS


 

Bid Protests Not Available

Similar Past Bids

Saint louis Missouri 21 Jun 2025 at 5 PM
Evans West virginia 10 Apr 2018 at 10 PM
Maple North carolina 16 Jan 2018 at 4 PM
Fort gordon Georgia 02 Apr 2009 at 2 PM
Chicago Illinois 10 Mar 2017 at 7 PM

Similar Opportunities

San diego California 27 Jul 2025 at 4 AM (estimated)
New york New york 29 Aug 2028 at 4 AM (estimated)
New york New york 29 Aug 2028 at 4 AM (estimated)
New york New york 29 Aug 2028 at 4 AM (estimated)
Dayton Ohio 03 Aug 2025 at 4 AM (estimated)