Federal Bid

Last Updated on 15 Jun 2017 at 8 AM
Sources Sought
Schofield barracks Hawaii

FY17 PKG A-007 Repair Building 452, Quad D, Schofield Barracks, Oahu, Hawaii

Solicitation ID W9128A-17-Z-0010
Posted Date 18 May 2017 at 12 AM
Archive Date 15 Jun 2017 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Not Specified
Agency Department Of Defense
Location Schofield barracks Hawaii United states
The purpose of this notice is to perform SOURCES SOUGHT/MARKET RESEARCH. This is NOT a Solicitation. This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract.

RESPONSES REQUESTED FROM ALL INTERESTED PRIME CONSTRUCTION FIRMS (LARGE AND SMALL BUSINESSES)


This U.S. Army Corps of Engineers, Honolulu District, is performing market research for the following potential construction requirement:

The U.S. Army Corps of Engineers, Honolulu District has a requirement for repairing or replacing deteriorated and failing building components. This project will repair and renovate Building 452, Quad D, Schofield Barracks, Oahu, Hawaii. The project consists of repairing or replacing a deteriorated three (3) story concrete framed historic building and failing building components. The first floor includes demolition and repair of existing interior walls, replace failing HVAC, lighting, electrical, communication, fire alarm, and plumbing to support two Company Headquarters. Four (4) new arms vaults will be added to the first floor and four (4) existing arms vaults will be repaired to current standards. Second and third floors repairs will include replacing failing window unit air conditioning, lighting, electrical, communication, fire alarm, plumbing, and roofing. Structural repairs to the entire building include floor framing strengthening to support code prescribed live loads; shear wall reconfiguration and/or strengthening; beams, columns, and foundation strengthening to meet seismic life-safety performance levels. Existing failed or failing windows will be removed and replaced with blast rated glazing systems while respecting historic aesthetics. Existing aged plumbing fixtures, piping, and existing hot water system will be removed and replaced. Existing failing air cooled packaged chiller and water heaters will be removed and replaced. Incidental lead based paint and asbestos containing material removal are included. Fire protection and mass notification systems/alarms will be repaired or installed to meet current Life Safety Code and base physical security requirements. Failing exterior finishes will require repainting and minor repair to spalled concrete. Site work shall consist of replacement of the existing utility laterals and appurtenances. A new drainage system is required to prevent flooding within the Quad. Turfing and other landscaping features are included.

This is a design-bid-build project.

The North American Industry Classification code (NAICS) is 236220 - Commercial and Institutional Building Construction. Size Standard for this project is $36.5 Million. The Government intends to award a firm-fixed price construction contract. The project magnitude is between $25,000,000 and $100,000,000. The Government may use responses to this market survey to make an appropriate acquisition decision for this project. The type of solicitation issued and the manner of advertisement may depend on the responses to this market survey.

Responses are requested from only interested PRIME CONSTRUCTION CONTRACTORS. Interested PRIME CONSTRUCTION CONTRACTORS should submit a narrative demonstrating their specific experience with renovating administrative and barracks buildings of similar type, size, value and location.

Respondents should also consider the geographical location of this project. Construction contracts awarded by the Army Corps of Engineers require compliance with EM 385-1-1 Safety Manual.

SUBMISSION REQUIREMENTS FOR RESPONSES TO THIS MARKET SURVEY shall include:

A. Your intent to submit for this project when it is formally advertised.
B. Name of firm with address, phone and point of contact. Indicate whether or not your firms is a U.S. firm or a foreign firm.
C. CAGE Code, DUNS number, or a copy of your Representation and Certification in SAM.gov.
D. Size of firm (large or small), to include category of small business if applicable, such as 8(a) small business, Historically Underutilized Business Zone (HUBZone) small business, Service Disabled Veteran Owned Small Business (SDVOSB), and/or Women Owned Small Businesses (WOSB).
E. Firm's Bonding Capacity - single and aggregate capability.
F. Contract data sheet identifying your recent and relevant experience that would qualify your firm to perform the specified type of work. This should include documentation of past specialized experience and past performance in performing repair, replacement, and/or renovation projects for facility types or their equivalent or similar commercial or institutional type multi story projects similar in size, type of work, complexity, magnitude (greater than $25M), and complexity. Submit no more than five (5) past completed projects within the past five (5) years from the date of this Sources Sought. Provide any additional information to further substantiate the capabilities of your firm to perform the specific type of work that this project involves.

Where to send responses:
Submit responses to Mr. Graeme Silva via email at [email protected] and Ms. Maria Buckner at [email protected]

Response deadline:
May 31, 2017, 1400 hours (Hawaiian Standard Time)

Place of Performance:
Bldg 452 in Quad D, Schofield Barracks, Hawaii

Contracting Office Address:
USACE District, Honolulu, Building 252, Walker Drive, Fort Shafter, HI 96858-5440

Point of Contact(s):
Mr. Graeme Silva, 808-835-4380
email address: [email protected]

Ms. Maria Buckner, 808-835-4389
Email address: [email protected]

Bid Protests Not Available

Similar Opportunities

No Similar Opportunities Found