RFQ
Hawaii

High Performance Benchtop Liquid Chromatograph Mass Spectrometer

Solicitation ID B23000403
Posted Date 31 Aug 2022 at 4 AM
Archive Date Not Specified
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Not Specified
Agency State Of Hawaii Eprocurement
Location Hawaii United states
The Department of Agriculture is soliciting bids for a high performance benchtop quadrupole high resolution mass spectrometer that combines a quadrupole, an ion routing multipole, and high resolution mass analyzer and features HCD and in-source fragmentation. The main use of this laboratory equipment would be for the detection of pesticide residue from open environment sampling. The equipment must have at least the following specifications or similar specification and quote must include: An OptaMax NG ion source API inlet source housing with x, y, and z probe positioning, integrated APCI functionality, a fixed on-axis view port, all gas and voltage connections are hard connected automatically producing worry free performance and ultimate reliability. OptaMax NG ion source housing includes one HESI spray insert and a calibration probe. For APCI applications APCI spray insert must be ordered separately. A vacuum system containing a 6-stage split-flow turbomolecular pump, which controls the vacuum in multiple regions. A Transfer Tube and an S-lens to capture and efficiently focus ions in a constricted beam. Ion Source which generates internal calibrant ions for real-time mass calibration of any mass spectrum. A resolving injection filter to pre-select ions for extended maintenance cycles. A bent flatapole to reduce noise by preventing neutrals and high-velocity clusters from entering the quadrupole mass filter. A segmented quadrupole mass filter in front of the curved ion trap (C-Trap) with a hyperbolic surface, which provide excellent peak shape and transmission. A high-field Mass Analyzer with enhanced FT transient processing resulting in resolving power from 15,000 up to 120,000 FWHM at m/z 200 and isotopic fidelity, m/z range of 40-3,000, with up to 22 Hz acquisition speed. An ion routing multipole for trapping of ions and higher-energy collisional dissociation (HCD). An independent syringe pump which are controlled via the data station for maximum flexibility. H-ESI II probe. Calibration probe. Windows 10 computer. License for Xcalibur software. Rough pump. System will be installed and tested by trained field service engineers to assure users that the components and system are functioning properly and that the installation specifications are met. Merkur CountKit NA. TRACEFINDER 5.1 SP3. PV PDU 2xL6-20R,2x6-20R,4x5-15R, NOT EU. Cal Solution, Flexmix, 2x10mL. Trade-In Service Deinstallation Labor (A Q Exactive Focus system is ready to be traded in).
Bid Protests Not Available

Similar Past Bids

Location Unknown 26 Jul 2018 at 3 PM
Howard Pennsylvania 18 Mar 2014 at 8 PM
Wright patterson air force base Ohio 18 Sep 2003 at 5 AM
Location Unknown 25 Jul 2008 at 4 AM
College station Arkansas 25 Aug 2011 at 4 PM

Similar Opportunities