Subcontract Requisition Number: 25490-CM-SRA-E00Z-00002
Submit Interest By: March 15, 2012
Estimated Budget: >$100,000 & <$500,000
Schedule:
• Issue Request for Proposal: April 2, 2012
• Award and Notice to Proceed: June 18, 2012
• Start Work: July 15, 2012
• All Work Complete: July 14, 2014
Safety Classification: NON-ITS
Additional Characteristic: None.
Quality Level: CM
Type of Subcontract: Firm Fixed Price
PROJECT DESCRIPTION AND LOCATION
The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is a complex of radioactive waste treatment processing facilities designed and constructed by Bechtel National, Inc. for the Department of Energy (DOE). The facility will process the Hanford Site tank waste and convert the waste into a stable glass form.
The Project site is located in the 200 East Area of the Hanford Reservation near Richland, Washington, along the Columbia River. The site elevation varies from 662 to 684 feet above mean sea level. Ambient temperature range is -23 degrees F minimum to 113 degrees F maximum, with relative humidity of 5% minimum to 100% maximum. The project design life is 40 years.
SCOPE OF WORK
SUBCONTRACTOR shall provide all labor and materials for commissioning to include testing of electrical protection, metering devices, and associated circuits for the Hanford Waste Treatment Plant Project, located at the Hanford Site, 22 miles north of Richland, WA. SUBCONTRACTOR shall provide all technical and professional personnel, labor, supervision, tools, consumables, expendable materials, test equipment, material storage, quality control, certifications, and other operations needed to commission the equipment indicated on design drawings. Design drawings, laptop, and software for relay interrogation will be provided by CONTRACTOR.
QUALITY ASSURANCE (QA) REQUIREMENTS
Programmatic Quality Assurance requirements for subcontracts performed in the WTP Jobsite will be "NP" (non permanent or temporary work, generally no QA Program required), "CM" (commercial quality based the requirements in DOE Order 414.1C), or "QL" (nuclear level quality based on the requirements in ASME NQA-1 2000). Bechtel may require, as an element of bidder pre-qualification, submission of a representative sample QA Program or Table of Contents copy. For QL subcontracts, the successful bidder's QA Program must be approved prior to award of the subcontract.
CODES (SAMPLE)
• UL Underwriters Laboratories, Inc.
• National Electric Code (NEC) ANSI/NFPA 70, Article 250 - Grounding
STANDARDS (SAMPLE)
• 29 CFR 1910-94 Occupational Safety and Health Standards
BIDDER REGISTRATION AND PRE-QUALIFICATION
Preliminary Pre-Qualification Requirements
The BNI Acquisition Services Subcontracts group is responsible for collection, evaluation, and internal publication of potential bidders' information for the purpose of pre-qualifying them to bid on any particular subcontract. As part of this process, BNI requires all potential offerors to register at the Supplier and Contractor Portal at: https://supplier.bechtel.com
Prior to being considered for bidding on a Request For Proposal (RFP) for this WTP web posting opportunity, potential bidders must complete and submit the required forms located at
http://www.hanfordvitplant.com/supplier_resources/qualification_process/
All information provided shall be strictly confidential.
Registration
All bidders must register with Bechtel National, Inc. for Work on the WTP Project.
If your company has registered previously, then only supplemental information should be sent to the Bechtel National, Inc. representative noted below.
Information to be provided by potential bidders must include:
• Dun and Bradstreet #:
• Company Name:
• Company Address:
• Contact Phone #:
• Contact Fax #:
• Contact Person:
• E-mail Address:
• Safety data and information
• Applicable work experience and Projects
WTP BACKGROUND
Information about the WTP Project can be found on http://www.hanfordvitplant.com
CONTACT
Bechtel National, Inc.
2435 Stevens Center Place
Richland, WA 99354
Attn: Lisa Carlin
Tel. No. 509-371-2078
Email address: [email protected]
Mailstop: MS14-3A