This request is an announcement for information/market research for planning purposes. This synopsis does not constitute a request for proposal, request for quote, invitation for bid nor does its issuance, in any way, restrict the Government as to its ultimate acquisition approach.

Kirtland AFB, New Mexico is seeking potential sources to provide a Microscope.

High Level Message

• AFM Modularity
o AFM scanner, controller, control and image processing software is the same across all AFM platforms
o Cost effective upgradeability and eliminates the need to learn different software platforms for different AFM systems
• Tip Scanning AFM scanner
o Eliminates potential damage to Piezoelectric (PZT) scanner when imaging in liquids
• True Environmental Control
o Only the tip and sample are exposed to the controlled environment
o PZT scanner, laser, detector and electronics are protected from the sample environment
• Single Pass Electric Measurements such as Kelvin Force Microscopy (KFM)
o Faster, higher spatial resolution and less susceptible to drift than "interleave" methods


Technical Specifications & Capabilities

• Contact Mode AFM
• AAC Mode AFM (oscillating cantilever mode)
• Lateral Force Microscopy (LFM)
• Phase Imaging
• Force Measurements
• Single Pass Kelvin Force Microscopy (a.k.a. Surface Potential Microscopy)
o Single Pass measurements are faster, higher spatial resolution and less susceptible to drift than "interleave" methods
• Electric Field Microscopy (EFM)
• Liquid Imaging
o System should include a fluid cell. Fluid cells must fit on interchangeable sample plates for heating, cooling or Acoustic AC modes.
 Fluid cell should be constructed of Kel-F (or similar) and be available in Teflon.
 Fluid cell should be held with quick clamping mechanism for fast assembly.
 Fluid cells should be priced economically (< $220 US) so that they can be conveniently replaced or spares provided to prevent cross-contamination of experiments or allow multiple users to prepare for experiments simultaneously
• True Environmental Control
o Must support an environmental chamber to be integrated with the microscope head for fast sample loading, have a gasket seal for complete isolation of gases in the chamber from the scanner and have a minimum of four ports for gas and/or electrical connectors. The chamber must be constructed of optically transparent and solvent/acid/base resistant material to allow viewing of the sample during operation. The chamber should be air-tight at moderate positive and negative pressures (as opposed to a "purge chamber" requiring a continuous flow of gasses). The system must be compatible and tolerant of a condensing environment as well. All scanner and detector electronic components should be sealed from the sample environment.
• All imaging should be done with a top down scanner (sample always stationary and tip/cantilever scanning) for sample size flexibility. This type of design also removes the danger of scanner damage from fluids.
• The system must have provisions for hermetically sealed scanner assemblies, with o-ring seals. Motorized vertical approach with the option of individual control of each motor for sample tilt compensation should be standard. Automatic, motorized engagement should be standard.
• Scanners must have interchangeable cantilever holders that are hermetically sealed from the environment and provide for the following modes of operation: Contact AFM, Oscillating probe/AC-AFM, EFM, LFM, etc. The system quoted should include such cantilever holders for AFM, AC-AFM, and KFM/EFM operation in air, fluid, or controlled environments. The system quoted should include a scanner with at least 9um x 9um range. Scanners and cantilever holders must allow a Z axis, 90 degree optical view for tip placement and laser alignment in air or under fluid.
• Sample environment must allow combinations of environmental conditions, such as electrochemistry, heating/cooling, and controlled gas/solvent environment without damage to the system.
• System must include full computer control and software package running under Windows XP. Computer should connect to system via USB or similar in order for computer to be user replaceable or laptop driven, if so desired, in order to keep computer upgrade costs low.

 